Skip to main content

Data Points

For more details about the data point events, please check here.

βœ… - No known limitation. 🚫 - No support. ⚠️ - Limited support.

Data Point NameDescriptionControl Unit TypeData TypeResolutionChange Threshold (1)Cleared upon appliance reset
hvac.cascade.hs{heatSourceId}.compressor.currentSpeedThe heat source's compressor working speed percentage. {heatSourceId} represents which heat source's compressor.βœ… xCU-HP
βœ… CU-HP
INT1 %10 %🚫
hvac.cascade.hs{heatSourceId}.emon.compressor.operationStatusRepresents operational status of an heat source's compressor in the HVAC system. {heatSourceId} represents which heat source's compressor. Possible values: IDLE, STARTUP, HEATING, COOLING, DEFROST, PASSIVE_DEFROST, SHUTOFFβœ… xCU-HP
βœ… CU-HP
STRING-ON-CHANGE🚫
hvac.cascade.hs{heatSourceId}.emon.compressor.powerCurrentThe current electrical power used by the heat source's compressor component in the HVAC cascade system. {heatSourceId} represents which heat source's compressor.βœ… xCU-HP
⚠️ CU-HP (3)
FLOAT1 W100 W🚫
hvac.compressor.currentSpeedThe compressor working speed percentageβœ… xCU-HP
βœ… CU-HP
INT1 %10 %🚫
hvac.domesticHotWater.dhw1.chargeStatusThe status of charge/boost mode of Domestic Hot Water circuit with one of the following values: INACTIVE, ACTIVEβœ… xCU-HP
βœ… CU-HP
STRING-ON-CHANGE🚫
hvac.domesticHotWater.dhw1.cylinderTemperatureCurrent cylinder temperature of Domestic Hot Water circuit.βœ… xCU-HP
βœ… CU-HP
FLOAT0.1 ºC1 ºC🚫
hvac.domesticHotWater.dhw{circuitId}.requestedLevelThe temperature level operating in Domestic Hot Water {circuitId} with one of the following values: OFF, ECOPLUS, ECO, COMFORTβœ… xCU-HP
βœ… CU-HP
STRING-ON-CHANGE🚫
hvac.emon.compressor.energyConsumptionTotal.centralHeatingThe energy consumption of the HVAC compressor, used for central heating.βœ… xCU-HP
🚫 CU-HP
FLOAT0.01 kWh0.1 kWhβœ…
hvac.emon.compressor.energyConsumptionTotal.centralHeating.lowResThe energy consumption of the HVAC compressor, used for central heating.🚫 xCU-HP
βœ… CU-HP
FLOAT1 kWh1 kWhβœ…
hvac.emon.compressor.energyConsumptionTotal.coolingThe energy consumption of the HVAC compressor, used for cooling.βœ… xCU-HP
🚫 CU-HP
FLOAT0.01 kWh0.1 kWhβœ…
hvac.emon.compressor.energyConsumptionTotal.cooling.lowResThe energy consumption of the HVAC compressor, used for cooling.🚫 xCU-HP
βœ… CU-HP
FLOAT1 kWh1 kWhβœ…
hvac.emon.compressor.energyConsumptionTotal.domesticHotWaterThe energy consumption of the HVAC compressor, used for domestic hot water (shower, sink, etc.).βœ… xCU-HP
🚫 CU-HP
FLOAT0.01 kWh0.1 kWhβœ…
hvac.emon.compressor.energyConsumptionTotal.domesticHotWater.lowResThe energy consumption of the HVAC compressor, used for domestic hot water (shower, sink, etc.).🚫 xCU-HP
βœ… CU-HP
FLOAT1 kWh1 kWhβœ…
hvac.emon.compressor.operationStatusRepresents operational status of a compressor in the HVAC system, with one of the following values: IDLE, HEATING_CENTRAL, HEATING_DOMESTIC_HOT_WATER, COOLING, DEFROSTβœ… xCU-HP
βœ… CU-HP
STRING-ON-CHANGE🚫
hvac.emon.compressor.powerCurrentThe current electrical power used by the compressor component in the HVAC system.βœ… xCU-HP
⚠️ CU-HP (3)
FLOAT1 W100 W🚫
hvac.emon.eheater.energyConsumptionTotal.centralHeatingThe energy consumption of the HVAC e-heater, used for central heating.βœ… xCU-HP
🚫 CU-HP
FLOAT0.01 kWh0.1 kWhβœ…
hvac.emon.eheater.energyConsumptionTotal.centralHeating.lowResThe energy consumption of the HVAC e-heater, used for central heating.🚫 xCU-HP
βœ… CU-HP
FLOAT1 kWh1 kWhβœ…
hvac.emon.eheater.energyConsumptionTotal.domesticHotWaterThe energy consumption of the HVAC e-heater, used for domestic hot water (shower, sink, etc.).βœ… xCU-HP
🚫 CU-HP
FLOAT0.01 kWh0.1 kWhβœ…
hvac.emon.eheater.energyConsumptionTotal.domesticHotWater.lowResThe energy consumption of the HVAC e-heater, used for domestic hot water (shower, sink, etc.).🚫 xCU-HP
βœ… CU-HP
FLOAT1 kWh1 kWhβœ…
hvac.emon.eheater.operationStatusRepresents operational status of a e-heater heater in the HVAC system, with one of the following values: IDLE, HEATING_CENTRAL, HEATING_DOMESTIC_HOT_WATER, DEFROSTβœ… xCU-HP
βœ… CU-HP
STRING-ON-CHANGE🚫
hvac.emon.eheater.powerCurrentThe current electrical power used by the e-heater component in the HVAC system.βœ… xCU-HP
⚠️ CU-HP (3)
FLOAT1 W100 W🚫
hvac.emon.energyConsumptionTotalThe overall energy consumption of the HVAC.βœ… xCU-HP
🚫 CU-HP
FLOAT0.01 kWh0.1 kWhβœ…
hvac.emon.energyConsumptionTotal.lowResThe overall energy consumption of the HVAC.🚫 xCU-HP
βœ… CU-HP
FLOAT1 kWh1 kWhβœ…
hvac.emon.energySupplyTotalThe overall energy supplied by the HVAC for heating and domestic hot water.βœ… xCU-HP
🚫 CU-HP
FLOAT0.01 kWh0.1 kWhβœ…
hvac.emon.energySupplyTotal.lowResThe overall energy supplied by the HVAC for heating and domestic hot water.🚫 xCU-HP
βœ… CU-HP
FLOAT1 kWh1 kWhβœ…
hvac.energyManagement.operationStatusRepresents the operational status of the heat source's energy management with one of the following values: NOT_CONNECTED, INACTIVE, ACTIVE_CENTRAL_HEATING, ACTIVE_DOMESTIC_HOT_WATERβœ… xCU-HP
βœ… CU-HP
STRING-ON-CHANGE🚫
hvac.heatingCircuit.hc{circuitId}.flowTemperatureThe flow temperature on Heating Circuit {circuitId}βœ… xCU-HP
βœ… CU-HP
FLOAT0.1 ºC1 ºC🚫
hvac.heatingCircuit.hc{circuitId}.roomTemperatureThe current room temperature where Heating Circuit {circuitId} operatesβœ… xCU-HP
βœ… CU-HP
FLOAT0.1 ºC1 ºC🚫
hvac.system.holidayMode.{holidayModeId}(2) Represents the holiday mode status, being the holiday mode affected determined by {holidayModeId}. Can be one of the following values: INACTIVE, PLANNED, ACTIVEβœ… xCU-HP
βœ… CU-HP
STRING-ON-CHANGE🚫
hvac.system.outdoorTemperatureThe current outside temperature of the air measured by the HVAC system.βœ… xCU-HP
βœ… CU-HP
FLOAT0.1 ºC0.5 ºC🚫
hvac.system.sensor.t0Sensor T0 value, representing the buffer tank temperatureβœ… xCU-HP
βœ… CU-HP
FLOAT0.1 ºC1 ºC🚫
hvac.system.sensor.tc0Sensor TC0 value, representing the return temperatureβœ… xCU-HP
βœ… CU-HP
FLOAT0.1 ºC1 ºC🚫
hvac.system.sensor.tc1Sensor TC1 value, representing the primary supply temperatureβœ… xCU-HP
βœ… CU-HP
FLOAT0.1 ºC1 ºC🚫

(1) - The change threshold is the minimum difference between the last value and the new value for an event to be sent.
(2) - This data point is only available when using HMI800 components.
(3) - For older heat pump generations with CU-HP platform, these data points are only available when an energy manager is connected to the heat pump. An energy manager can be connected by using the dedicated energy manager interface of the Local API interface (see Local API documentation in this Developer Portal). An active energy manager is indicated by hvac.energyManagement.operationStatus.