| Data Point Name | Description | Control Unit Type | Data Type | Resolution | Change Threshold (1) | Cleared upon appliance reset |
|---|---|---|---|---|---|---|
hvac.cascade.hs{heatSourceId}.compressor.currentSpeed | The heat source's compressor working speed percentage. {heatSourceId} represents which heat source's compressor. | β
xCU-HP β CU-HP | INT | 1 % | 10 % | π« |
hvac.cascade.hs{heatSourceId}.emon.compressor.operationStatus | Represents operational status of an heat source's compressor in the HVAC system. {heatSourceId} represents which heat source's compressor. Possible values: IDLE, STARTUP, HEATING, COOLING, DEFROST, PASSIVE_DEFROST, SHUTOFF | β
xCU-HP β CU-HP | STRING | - | ON-CHANGE | π« |
hvac.cascade.hs{heatSourceId}.emon.compressor.powerCurrent | The current electrical power used by the heat source's compressor component in the HVAC cascade system. {heatSourceId} represents which heat source's compressor. | β
xCU-HP β οΈ CU-HP (3) | FLOAT | 1 W | 100 W | π« |
hvac.compressor.currentSpeed | The compressor working speed percentage | β
xCU-HP β CU-HP | INT | 1 % | 10 % | π« |
hvac.domesticHotWater.dhw1.chargeStatus | The status of charge/boost mode of Domestic Hot Water circuit with one of the following values: INACTIVE, ACTIVE | β
xCU-HP β CU-HP | STRING | - | ON-CHANGE | π« |
hvac.domesticHotWater.dhw1.cylinderTemperature | Current cylinder temperature of Domestic Hot Water circuit. | β
xCU-HP β CU-HP | FLOAT | 0.1 ΒΊC | 1 ΒΊC | π« |
hvac.domesticHotWater.dhw{circuitId}.requestedLevel | The temperature level operating in Domestic Hot Water {circuitId} with one of the following values: OFF, ECOPLUS, ECO, COMFORT | β
xCU-HP β CU-HP | STRING | - | ON-CHANGE | π« |
hvac.emon.compressor.energyConsumptionTotal.centralHeating | The energy consumption of the HVAC compressor, used for central heating. | β
xCU-HP π« CU-HP | FLOAT | 0.01 kWh | 0.1 kWh | β |
hvac.emon.compressor.energyConsumptionTotal.centralHeating.lowRes | The energy consumption of the HVAC compressor, used for central heating. | π« xCU-HP β CU-HP | FLOAT | 1 kWh | 1 kWh | β |
hvac.emon.compressor.energyConsumptionTotal.cooling | The energy consumption of the HVAC compressor, used for cooling. | β
xCU-HP π« CU-HP | FLOAT | 0.01 kWh | 0.1 kWh | β |
hvac.emon.compressor.energyConsumptionTotal.cooling.lowRes | The energy consumption of the HVAC compressor, used for cooling. | π« xCU-HP β CU-HP | FLOAT | 1 kWh | 1 kWh | β |
hvac.emon.compressor.energyConsumptionTotal.domesticHotWater | The energy consumption of the HVAC compressor, used for domestic hot water (shower, sink, etc.). | β
xCU-HP π« CU-HP | FLOAT | 0.01 kWh | 0.1 kWh | β |
hvac.emon.compressor.energyConsumptionTotal.domesticHotWater.lowRes | The energy consumption of the HVAC compressor, used for domestic hot water (shower, sink, etc.). | π« xCU-HP β CU-HP | FLOAT | 1 kWh | 1 kWh | β |
hvac.emon.compressor.operationStatus | Represents operational status of a compressor in the HVAC system, with one of the following values: IDLE, HEATING_CENTRAL, HEATING_DOMESTIC_HOT_WATER, COOLING, DEFROST | β
xCU-HP β CU-HP | STRING | - | ON-CHANGE | π« |
hvac.emon.compressor.powerCurrent | The current electrical power used by the compressor component in the HVAC system. | β
xCU-HP β οΈ CU-HP (3) | FLOAT | 1 W | 100 W | π« |
hvac.emon.eheater.energyConsumptionTotal.centralHeating | The energy consumption of the HVAC e-heater, used for central heating. | β
xCU-HP π« CU-HP | FLOAT | 0.01 kWh | 0.1 kWh | β |
hvac.emon.eheater.energyConsumptionTotal.centralHeating.lowRes | The energy consumption of the HVAC e-heater, used for central heating. | π« xCU-HP β CU-HP | FLOAT | 1 kWh | 1 kWh | β |
hvac.emon.eheater.energyConsumptionTotal.domesticHotWater | The energy consumption of the HVAC e-heater, used for domestic hot water (shower, sink, etc.). | β
xCU-HP π« CU-HP | FLOAT | 0.01 kWh | 0.1 kWh | β |
hvac.emon.eheater.energyConsumptionTotal.domesticHotWater.lowRes | The energy consumption of the HVAC e-heater, used for domestic hot water (shower, sink, etc.). | π« xCU-HP β CU-HP | FLOAT | 1 kWh | 1 kWh | β |
hvac.emon.eheater.operationStatus | Represents operational status of a e-heater heater in the HVAC system, with one of the following values: IDLE, HEATING_CENTRAL, HEATING_DOMESTIC_HOT_WATER, DEFROST | β
xCU-HP β CU-HP | STRING | - | ON-CHANGE | π« |
hvac.emon.eheater.powerCurrent | The current electrical power used by the e-heater component in the HVAC system. | β
xCU-HP β οΈ CU-HP (3) | FLOAT | 1 W | 100 W | π« |
hvac.emon.energyConsumptionTotal | The overall energy consumption of the HVAC. | β
xCU-HP π« CU-HP | FLOAT | 0.01 kWh | 0.1 kWh | β |
hvac.emon.energyConsumptionTotal.lowRes | The overall energy consumption of the HVAC. | π« xCU-HP β CU-HP | FLOAT | 1 kWh | 1 kWh | β |
hvac.emon.energySupplyTotal | The overall energy supplied by the HVAC for heating and domestic hot water. | β
xCU-HP π« CU-HP | FLOAT | 0.01 kWh | 0.1 kWh | β |
hvac.emon.energySupplyTotal.lowRes | The overall energy supplied by the HVAC for heating and domestic hot water. | π« xCU-HP β CU-HP | FLOAT | 1 kWh | 1 kWh | β |
hvac.energyManagement.operationStatus | Represents the operational status of the heat source's energy management with one of the following values: NOT_CONNECTED, INACTIVE, ACTIVE_CENTRAL_HEATING, ACTIVE_DOMESTIC_HOT_WATER | β
xCU-HP β CU-HP | STRING | - | ON-CHANGE | π« |
hvac.heatingCircuit.hc{circuitId}.flowTemperature | The flow temperature on Heating Circuit {circuitId} | β
xCU-HP β CU-HP | FLOAT | 0.1 ΒΊC | 1 ΒΊC | π« |
hvac.heatingCircuit.hc{circuitId}.roomTemperature | The current room temperature where Heating Circuit {circuitId} operates | β
xCU-HP β CU-HP | FLOAT | 0.1 ΒΊC | 1 ΒΊC | π« |
hvac.system.holidayMode.{holidayModeId} | (2) Represents the holiday mode status, being the holiday mode affected determined by {holidayModeId}. Can be one of the following values: INACTIVE, PLANNED, ACTIVE | β
xCU-HP β CU-HP | STRING | - | ON-CHANGE | π« |
hvac.system.outdoorTemperature | The current outside temperature of the air measured by the HVAC system. | β
xCU-HP β CU-HP | FLOAT | 0.1 ΒΊC | 0.5 ΒΊC | π« |
hvac.system.sensor.t0 | Sensor T0 value, representing the buffer tank temperature | β
xCU-HP β CU-HP | FLOAT | 0.1 ΒΊC | 1 ΒΊC | π« |
hvac.system.sensor.tc0 | Sensor TC0 value, representing the return temperature | β
xCU-HP β CU-HP | FLOAT | 0.1 ΒΊC | 1 ΒΊC | π« |
hvac.system.sensor.tc1 | Sensor TC1 value, representing the primary supply temperature | β
xCU-HP β CU-HP | FLOAT | 0.1 ΒΊC | 1 ΒΊC | π« |
(1) - The change threshold is the minimum difference between the last value and the new value for an event to be sent.
(2) - This data point is only available when using HMI800 components.
(3) - For older heat pump generations with CU-HP platform, these data points are only available when an energy manager is connected to the heat pump. An energy manager can be connected by using the dedicated energy manager interface of the Local API interface (see Local API documentation in this Developer Portal). An active energy manager is indicated by hvac.energyManagement.operationStatus.